Ambirad boiler manuals

Ambirad boiler manuals pdf download

The Ambi-stat control panel is designed for use with Ambi-Rad warm air heater units. The controller comprises of an electronic time clock, air sensing thermostat and frost protection thermostat, a HEAT / V E N T / O F F switch – giving ‘Fan only’ operation on air heaters and ‘Heating OFF’ facilities (except for frost protection for use during holidays etc.). Lockout indication/Reset Switch, and clock override function. Note Lockout Indication/Reset connection for use with automatic ignition units only.

Temperature sensing The selection of the correct position for the control panel is particularly important. The unit must be fitted at a point which will be generally representative of the heated area. Draughty areas, or areas subjected to direct heat (e.g. from the sun, radiators, heaters outlets etc.) or areas where the air movement is relatively stagnant (e.g. recesses are all positions to be avoided when siting the unit. Ideally units should be mounted 1.5m from the floor

Get the manual here download now

Ambirad manual-pdfAmbirad boiler

Alpha boiler manuals

Alpha boiler manuals pdf Download

The Alpha Range of boilers are wall mounted, fan assisted room-sealed combination boilers. Heat output is controlled by a modulating gas valve. The boilers, providing both central heating and domestic hot water at mains pressure, are designed for use with a fully pumped, sealed and pressurised heating system using only Natural Gas.

The boilers are supplied with a pump, diverter valve, pressure relief valve, expansion vessel and pressure gauge fully assembled and tested. As supplied, the Alpha 240E and 240P boilers will automatically modulate to provide central heating outputs between 9.3 and 23.3 kW (31 700 and 79 500 Btu/h). The Alpha 280E and 280P boilers will provide central heating outputs between 9.3 and 28.0 kW (31 700 and 95 500 Btu/h).

The maximum output available for domestic hot water is 23.3 kW (79 500 Btu/h), capable of providing 9.5 litres/min with a temperature rise of 35°C for the Alpha 240E and 240P boilers, and 28.0 kW (95 500 Btu/h), capable of providing 11.4 litres/min with a temperature rise of 35°C for the Alpha 280E and 280P boilers.
 

There are many more alpha boiler manuals available

Alpha boiler manuals-pdf

Alpha boiler

ACV boiler manuals

ACV boiler manuals pdf download

 

These instructions are an integral part of the equipment to which they relate and must be handed to the user.
The product must be installed and serviced by qualified engineers in accordance with the regulations in force.
ACV declines all liability for any damage caused as a result of incorrect installation or in the event of the use of appliances or accessories that are not specified by ACV.
We recommend that you have your system serviced each year by a qualified engineer. In normal operation the burner starts automatically if the temperature of the boiler is below setpoint Before carrying out any work on the boiler, isolate it from the electrical supply at the switch on the external control box. Also move the main switch on the control panel to “OFF”.

Find out more from the boiler manual ………….

acv boiler manuals
ACV boiler manuals